Skip to main navigation Skip to search Skip to main content

Myoelectric control algorithm for robot-assisted therapy: A hardware-in-the-loop simulation study

  • Juan C. Yepes
  • , Mario A. Portela
  • , Álvaro J. Saldarriaga
  • , Vera Z. Pérez
  • , Manuel J. Betancur

Research output: Contribution to scientific journalArticle in an indexed scientific journalpeer-review

7 Scopus citations

Abstract

Background: A direct blow to the knee is one way to injure the anterior cruciate ligament (ACL), e.g., during a football or traffic accident. Robot-assisted therapy (RAT) rehabilitation, simulating regular walking, improves walking and balance abilities, and extensor strength after ACL reconstruction. However, there is a need to perform RAT during other phases of ACL injury rehabilitation before attempting an advanced exercise such as walking. This paper aims to propose a myoelectric control (MEC) algorithm for a robot-assisted rehabilitation system, "Nukawa", to assist knee movement during these types of exercises, i.e., such as in active-assisted extension exercises. Methods: Surface electromyography (sEMG) signal processing algorithm was developed to detect the motion intention of the knee joint. The sEMG signal processing algorithm and the movement control algorithm, reported by the authors in a previous publication, were joined together as a hardware-in-the-loop simulation to create and test the MEC algorithm, instead of using the actual robot. Experiments and results: An experimental protocol was conducted with 17 healthy subjects to acquire sEMG signals and their lower limb kinematics during 12 ACL rehabilitation exercises. The proposed motion intention algorithm detected the orientation of the intention 100% of the times for the extension and flexion exercises. Also, it detected in 94% and 59% of the cases the intensity of the movement intention in a comparable way to the maximum voluntary contraction (MVC) during extension exercises and flexion exercises, respectively. The maximum position mean absolute error was 0.1 0. 1 6.36. 3 and 0.3 0. 3 for the hip, knee, and ankle joints, respectively. Conclusions: The MEC algorithm detected the intensity of the movement intention, approximately, in a comparable way to the MVC and the orientation. Moreover, it requires no prior training or additional torque sensors. Also, it controls the speed of the knee joint of Nukawa to assist the knee movement, i.e., such as in active-assisted extension exercises.

Original languageEnglish
Article number622
JournalBioMedical Engineering Online
Volume18
Issue number1
DOIs
StatePublished - 3 Jan 2019

Bibliographical note

Publisher Copyright:
© 2019 The Author(s).

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 3 - Good Health and Well-being
    SDG 3 Good Health and Well-being

Keywords

  • Assistive robotics
  • Biomedical signal analysis
  • Electromyography (EMG) control
  • Myoelectric control
  • Powered exoskeletons

Types Minciencias

  • Artículos de investigación con calidad A2 / Q2

Fingerprint

Dive into the research topics of 'Myoelectric control algorithm for robot-assisted therapy: A hardware-in-the-loop simulation study'. Together they form a unique fingerprint.

Cite this