Abstract
The objective of the present research work was to carry out a numerical analysis by means of CFD of a flat plate solar collector, in addition to a comparison with experimental results. The working fluid reached a maximum outlet temperature of 20.16 °C at 12:00the value of solar radiation was determined for the geographical coordinates latitude-0.2252 and longi-tude-77.84; similarly, at this time it was possible to obtain a temperature of 27.12 °C on the collector surface, as peak value. The lowest performance of the heat transfer device was determined at 10:00 with an outlet water temperature and maximum temperature on the collector surface of 18.65 and 20.48 °C, respec-tively. The experimental results showed a maximum temperature of 20.93 °C and a minimum temperature of 19.4 °C, resulting in a 4.01 % error between the computational simulation and the experimental data.
| Translated title of the contribution | NUMERICAL ANALISYS OF A WATER HEATING SYSTEM USING A FLAT PLATE SOLAR COLLECTOR |
|---|---|
| Original language | English |
| Pages (from-to) | 97-106 |
| Number of pages | 10 |
| Journal | Ingenius |
| Volume | 2020 |
| Issue number | 24 |
| DOIs | |
| State | Published - 1 Jul 2020 |
Bibliographical note
Publisher Copyright:© 2020, Universidad Politecnica Salesiana. All rights reserved.
Keywords
- CFD simulation
- Collector
- solar energy
- temperature
Types Minciencias
- Artículos de investigación con calidad D
Fingerprint
Dive into the research topics of 'NUMERICAL ANALISYS OF A WATER HEATING SYSTEM USING A FLAT PLATE SOLAR COLLECTOR'. Together they form a unique fingerprint.Cite this
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver