Skip to main navigation Skip to search Skip to main content

Quantification of Pluronic F127 used on PLGA nanoparticle preparation and comparing purification techniques by centrifugation, tangential flow filtration, and ultrafiltration

  • Esneyder Ruiz
  • , Víctor H. Orozco
  • , Lina M. Hoyos
  • , Luis F. Giraldo

Research output: Contribution to scientific journalArticle in an indexed scientific journalpeer-review

7 Scopus citations

Abstract

Emerging research in polymeric nanoparticles (PNP) in the field of drug delivery systems focuses on the preferable use of biocompatible materials like poly(lactic-co-glycolic) acid (PLGA). However, the substantial use of surfactant in achieving colloidal stability requires its subsequent elimination to avoid side effects. This study aimed to establish suitable conditions for detecting and quantifying Pluronic® F127 (F127), a non-ionic surfactant widely used for this specific purpose, through a precise Size Exclusion Chromatography (SEC) method. Then, comparing the F127 removal efficacy via three purification techniques: Centrifugation (Cf), Ultrafiltration (UF), and tangential flow filtration (TFF), determining the minor influence of surfactant removal on the colloidal and morphological properties of surfactant-free PLGA suspensions. Thus, to determine the most suitable strategy for purifying PNP. The initial results of the SEC method revealed two distinct molar mass distributions of F127, associated with a blend of triblock alongside a minor fraction of homopolymer or diblock. The method exhibited a high linear correlation (R2 0.99991) for surfactant concentrations ranging from 0.3 to 14.7 mg/mL. While assessing the three purification techniques, UF demonstrated proficiency in concentrating nanoparticle suspensions, albeit tending to retain a significant portion of the surfactant. In contrast, Cf displayed a remarkable capability in removing more than 90 % of the incorporated F127. However, Cf recovered only 60 % of the initial nanoparticles, predominantly eliminating smaller diameter particles. Conversely, TFF demonstrated high efficacy in surfactant removal, requiring an extended washing process and leading to minimal nanoparticle loss while leaving the colloidal variables unaffected.

Original languageEnglish
Article number112887
JournalEuropean Polymer Journal
Volume208
DOIs
StatePublished - 25 Mar 2024

Bibliographical note

Publisher Copyright:
© 2024 Elsevier Ltd

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 9 - Industry, Innovation, and Infrastructure
    SDG 9 Industry, Innovation, and Infrastructure

Keywords

  • Centrifugation
  • PLGA
  • Size Exclusion Chromatography
  • Surfactant
  • Tangential Flow Filtration
  • Ultrafiltration

Types Minciencias

  • Artículos de investigación con calidad A1 / Q1

Fingerprint

Dive into the research topics of 'Quantification of Pluronic F127 used on PLGA nanoparticle preparation and comparing purification techniques by centrifugation, tangential flow filtration, and ultrafiltration'. Together they form a unique fingerprint.

Cite this