Efectividad analgésica de clonidina vs. morfina como coadyuvantes de la anestesia espinal con bupivacaína hiperbárica en pacientes sometidas a cesárea

J. M.García Montes, C. T.Lizcano Contreras, M. Torres, L. F. Álvarez-Hernández, L. M. Martínez-Sánchez, E. Vallejo Agudelo

    Producción científica: Contribución a una revistaArtículo en revista científica indexadarevisión exhaustiva

    Resumen

    Introduction: The main adjuvants of bupivacaine are opioids and clonidine; the first opioid used by the epidural route was morphine, which since 1979 has demonstrated benefit of its intrathecal and extradural use, for the management of chronic and postoperative pain. Objective: Determine the analgesic effectiveness of morphine vs. clonidine added to spinal anesthesia with hyperbaric bupivacaine in patients undergoing cesarean section. Method: A quasi-experimental correlational clinical trial. 60 parturients, carrying a singleton fetus at term, scheduled to undergo cesarean section under spinal anesthesia were randomized in one of the two groups. Group BC (n = 30) received 10 mg hyperbaric bupivacaine and 75 Μg clonidine; Group BM (n = 30) 10 mg hyperbaric bupivacaine and 100 Μg morphine. Results: Statistically significant difference, p = 0.02, were found between the time of 14.5 ± 2.1 hours since the administration of anesthesia to the application of the first dose of additional analgesia in morphine group vs. clonidine group 8.18 ± 2.91 hours. Pain at the time of the application of postoperative analgesia was superior in clonidine group with 6.4 ± 1.0 points in AVE vs. morphine with 0.93 ± 2.4 points. p = 0.001. AVE values were also significantly higher for clonidine in relation to morphine at 6, 12 and 18 hours. No significant hemodynamic and respiratory changes occurred in either group. For morphine the most frequent side effect was itching in 66.7 % of patients. The level of sedation was the same for clonidine and morphine in all the patients. Conclusions: Add 100 Μg of morphine to hyperbaric bupivacaine for spinal anesthesia prolongs the time and significantly improves quality of the postoperative analgesic period greater than 75 Μg of clonidine. The most common side effect is itching.

    Título traducido de la contribuciónAnalgesic effectiveness of clonidine vs. morphine as coadjuvants to spinal anesthesia with hyperbaric bupivacaine in patients undergoing cesarean section
    Idioma originalEspañol
    Páginas (desde-hasta)207-213
    Número de páginas7
    PublicaciónRevista de la Sociedad Espanola del Dolor
    Volumen25
    N.º4
    DOI
    EstadoPublicada - 1 jul. 2018

    Nota bibliográfica

    Publisher Copyright:
    © 2018 Ediciones Doyma, S.L. All rights reserved.

    Palabras clave

    • Analgesia
    • Cesarean section
    • Clonidine
    • Morphine

    Huella

    Profundice en los temas de investigación de 'Efectividad analgésica de clonidina vs. morfina como coadyuvantes de la anestesia espinal con bupivacaína hiperbárica en pacientes sometidas a cesárea'. En conjunto forman una huella única.

    Citar esto