Resumen
The objective of the present research work was to carry out a numerical analysis by means of CFD of a flat plate solar collector, in addition to a comparison with experimental results. The working fluid reached a maximum outlet temperature of 20.16 °C at 12:00the value of solar radiation was determined for the geographical coordinates latitude-0.2252 and longi-tude-77.84; similarly, at this time it was possible to obtain a temperature of 27.12 °C on the collector surface, as peak value. The lowest performance of the heat transfer device was determined at 10:00 with an outlet water temperature and maximum temperature on the collector surface of 18.65 and 20.48 °C, respec-tively. The experimental results showed a maximum temperature of 20.93 °C and a minimum temperature of 19.4 °C, resulting in a 4.01 % error between the computational simulation and the experimental data.
| Título traducido de la contribución | ANÁLISIS NUMÉRICO DE UN SISTEMA DE CALENTAMIENTO DE AGUA UTILIZANDO UN COLECTOR SOLAR DE PLACA PLANA |
|---|---|
| Idioma original | Inglés |
| Páginas (desde-hasta) | 97-106 |
| Número de páginas | 10 |
| Publicación | Ingenius |
| Volumen | 2020 |
| N.º | 24 |
| DOI | |
| Estado | Publicada - 1 jul 2020 |
Nota bibliográfica
Publisher Copyright:© 2020, Universidad Politecnica Salesiana. All rights reserved.
Tipos de Productos Minciencias
- Artículos de investigación con calidad D
Huella
Profundice en los temas de investigación de 'ANÁLISIS NUMÉRICO DE UN SISTEMA DE CALENTAMIENTO DE AGUA UTILIZANDO UN COLECTOR SOLAR DE PLACA PLANA'. En conjunto forman una huella única.Citar esto